Property Inspector 3.0


90+ Operations that can be done in seconds that are difficult or impossible with LabVIEW:

  1. Find all VIs with blank Descriptions
  2. Find all VIs with Descriptions that are not blank
  3. Replace several blank Descriptions in a single click
  4. Append template text to all Descriptions
  5. Prepend template text to all Descriptions
  6. Find all VIs with various template Descriptions and remove them all
  7. Find all VIs by eliminating those with a GLOBAL EXCLUSION™
  8. Find all VIs with Allow Debugging Enabled
  9. Disable Allow Debugging on all those VIs
  10. Re-enable Allow Debugging on the same VIs after testing performance
  11. Find all VIs with Automatic Error Handling enabled
  12. Disable Automatic Error Handing for all those VIs
  13. Find all VIs with History Text
  14. Find all VIs with History Text by a specific user name
  15. Clear the history text for all those VIs
  16. Find all VIs with Separate compiled code from source disabled
  17. Enable Separate compiled code from source for those VIs
  18. Find all VIs not in memory
  19. Find All VIs that are broken
  20. Find all VIs in earlier LV versions
  21. Find all VIS that are not in memory, broken AND in an earlier LV Version
  22. Find all VIs with Password Protection enabled
  23. Remove Password Protection for several VIs
  24. Turn on Password Protection for several VIs
  25. Lock several VIs
  26. Find all VIs with Reentrancy enabled
  27. Find all VIs with Reentrant set to Shared or Preallocated
  28. Find all VIS with Reentrancy enabled AND set to Preallocated
  29. Change Reentrant setting for several VIs
  30. Find all VIS where inlining is allowed
  31. Set inline subvi for multiple VIs
  32. Find all VIs with any custom Run Time Menu
  33. Remove the Run Time menu for all those VIs
  34. Find all VIS with a custom Window Title
  35. Find all VIs set to show their window when called
  36. Find all VIs with transparency enabled
  37. Set transparency on multiple VIs
  38. Find all VIs set to show the menu bar
  39. Find all VIs set to suspend when called
  40. Find all VIs set to Monitor 1, Monitor 2 or default
  41. Change all VIs set to Monitor 1 to 2 and Monitor 2 to 1
  42. Find all VIs with Window Behavior set to Modal
  43. Find all VIs with Window Behavior set to Floating
  44. Find all VIs set to a specific Execution System
  45. Find the oldest VIs in the project
  46. Find the most recent VIs in the project
  47. Find that VI last modified on a specific date
  48. Find all controls in a project
  49. Select all Global VIs in a project
  50. Find all VIs contained in all classes
  51. Find all VIs contained in a class except in a specific class
  52. Find all VIs not contained in any class
  53. Find all VIs in all libraries
  54. Find all VIs not in any Library
  55. Find all LLBs in a project
  56. Find all DAQmx Channels
  57. Find all DAQmx Tasks
  58. Find all DAQmx Scales
  59. Find all DAQmx Channels, Tasks and Scales
  60. Highlight multiple objects scattered in the Project Explorer window in a single click
  61. List All VIs that are modified without closing the project
  62. Save a subset of modified VIs in a single operation
  63. Save all VIs, not just the modified ones
  64. Sort all VIs by static data memory size
  65. Sort all VIs by code size
  66. Sort all VIs by file size
  67. Sort all VIs by Revision Number
  68. Sort all VIs by date modified
  69. Sort all VIs by Name
  70. Sort all VIs by Path
  71. Sort all VIs by Type
  72. Sort all VIs by number of callers
  73. Sort all VIs by number of clones
  74. Sort all VIs by code complexity
  75. Sort all LLBs by date
  76. Sort all LLBs by size
  77. Sort all virtual folders by date
  78. Unsort all VIs to revert back to the project order
  79. Reset Revision Number for several VIs
  80. Set Revision Number for several VIs
  81. Delete several VIs from the project and several LLBs in a single operation
  82. Delete single VI from auto-populating folder
  83. Delete several VIs from several auto-populating folders in a single operation
  84. Open any number of front panels in a single operation
  85. Close the same front panels in a single operation
  86. Open any number of block diagram in a single operation
  87. Run a custom VI script on any number of VIs
  88. Run a custom search on the entire project using one VI script
  89. Run a standard VI Analyzer check and highlight the failed VIs in the Project Explorer Window
  90. Run a standard Quick Drop script on any number of VI’s front panels
  91. Run a standard Quick Drop script on any number of VI’s block diagrams
  92. Customize a standard Quick Drop script to edit any number of VIs
  93. Perform repetitive edits efficiently with a one-click history of the last 9 edit operations

This product is available on the LabVIEW Tools Network. Download a free 30 day trial with unrestricted usage.

Order now for $179 by calling 800-422-1523 or pay with PayPal. Delivery by email in about two business days.

 



Last updated on: February 14th, 2019